Corporate Information & Contacts Distributors & Purchasing Options Catalog Requests & Downloads Customer Service & Drawings Surplus Stock & Promotions

Normaling Descriptions

 
T=Tip  TN=Tip Normal
R=Ring RN=Ring Normal
S=Sleeve   SN=Sleeve Normal
Physical:
  A Row: T, R, S, wired out to rear termination 
     connector. TN, RN are strapped to 
     B Row TN, RN respectively.
  B Row: T, R, S, wired out to rear termination 
     connector. TN, RN are strapped to 
     A Row TN, RN respectively.
Function: Signal from A Row is automatically looped to 
  B Row. If a patchcord is inserted in the A Row or 
  B Row Jack, the automatic looping is broken. 
Features and Benefits: Automatic Looping.
   
Physical:
  A Row: T, R, S, wired out to rear termination 
     connector. T, R are strapped to B Row
     TN, RN respectively.
  B Row: T, R, S, wired out to rear termination 
     connector. TN, RN are strapped to
     A Row T, R respectively.
Function: Signal from A Row is automatically looped to
  B Row. If a patchcord is inserted in the A Row, signal is
  still looped to B Row. However, if a patchcord is
  inserted in the B Row, the automatic looping is broken. 
Features and Benefits: Automatic Looping, Non-
  intrusive Signal Monitoring when A Row is patched.
   
Physical: 
  A Row: T, R, S, TN, RN wired out to
     rear termination connector.
  B Row: T, R, S, TN, RN wired out to
     rear termination connector.
Function: Full, Half, Dual or NoNs.
Benefits: 
 
1. Flexibility: Full, Half, Dual or No Normals can be 
     strapped per circuit at the rear termination 
     connector.
  2.Normaling can be easily changed in future.
   
Physical:
  A Row: T, R, S, wired out to rear 
     termination connector. 
  B Row: T, R, S, wired out to rear 
     termination connector.
Function: A Row circuits are completed independent 
  from B Row circuits.
Features and Benefits: Simple patching.
   
Physical:
  A Row: T, R, S, wired out to rear termination 
     connector. T, R, are strapped to B Row TN,
     RN respectively.
  B Row: T, R, S, wired out to rear termination 
     connector. T, R, are strapped to A Row TN,
     RN respectively.
Function: Signal from A Row is automatically looped to
  B Row. If a patchcord is inserted in the A Row or the 
  B Row (but NOT BOTH), signal is still looped between
  A Row and B Row. However, if patchcords are inserted
  in both A Row AND B Row, the automatic looping is
  broken. 
Features and Benefits: Automatic Looping, Non
  intrusive Signal Monitoring from either A Row or B
  Row.
   
Physical: 
  A Row: T, R, S, TN, RN, SN wired out to rear termination connector.
  B Row: T, R, S, TN, RN, SN wired out to rear termination connector.
Function: Full, Half, Dual or No Normals.
Benefits: 
 
1. Flexibility: Full, Half, Dual or No Normals can be
     strapped per circuit at the rear termination
     connector. 
  2. Normaling can be easily changed in future.
  3. Full control of Sleeves at rear termination connector.
   
Physical:
  A Row: T, R, S, wired out to rear termination 
     connector. TN, RN are strapped to
     B Row TN, RN respectively. In
     addition T, R are strapped to C Row T, R
     respectively.
  B Row: T, R, S, wired out to rear termination 
     connector. TN, RN are strapped to A 
     Row TN, RN respectively.
  C Row: T, R are strapped to A Row T, R 
     respectively.
Function: Signal from A Row is automatically looped to 
  B Row. If a patchcord is inserted in the A Row or 
  B Row Jack, the automatic looping is broken. C Row
  always monitors A Row signal regardless of patching
  state in A Row or B Row.
Features and Benefits: Automatic Looping from A Row
  to B Row. Monitoring of A Row signal always available
  in C Row.